Omicron Cmc 356 User Manual Pdf
- Omicron Cmc 430
- Omicron Cmc 256 Manual
- Omicron Cmc 356 Manual Pdf
- Omicron Cmc
- Omicron 356 Manual
- Omicron Cmc 356 User Manual
Omicron 356 Manual Get Download Omicron Cmc 356 User Manual And Access Online. Unlimited PDF Ebooks Download. Omicron 100TX to 100FX-SC Converter Connects the CMC 356, CMC 353 Measurement Systems. Jul 03, 2017 Get omicron cpc 100 user manual PDF file for free from our online library PDF file: omicron cpc 100 user manual Page: 1 2. OMICRON CPC 100 USER MANUAL The main topic of the following eBook is focused on OMICRON CPC 100 USER MANUAL, however it did not enclosed the possibility of other extra info as well as details concerning the topic.
- Consult OMICRON electronics's entire OMICRON Products and Solutions catalogue on DirectIndustry. Protection and recloser control testing 6-phase test sets + CMC 356 Universal relay test set and commissioning tool Test Universe PC software suite for advanced secondary testing with CMC test sets CMC 256plus High-precision relay test set PTL.
- Nov 24, 2015 On this page you can read or download omicron cmc 356 user manual in PDF format. If you don't see any interesting for you, use our search form on bottom ↓. CMC Exam Handbook - AACN. 4 CmC CertifiCation Program CMC ® (Cardiac Medicine Certification) is a nursing subspecialty designed for specialty certified nurses who.
- Oct 01, 2015 Choosing a Backup Generator Plus 3 LEGAL House Connection Options - Transfer Switch and More - Duration: 12:39. Bailey Line Road Recommended for you.
- Hire the Omicron CMC 356, a Universal Tool for Substation Commissioning, used by commissioning engineers worldwide. Hire online today with Inlec UK - Next Day Delivery Also Available.
1
Testing with GOOSE and Sampled Values functionality requires software licences for
the corresponding configuration modules
2
For line input voltages below 230 V, a derating of the simultaneously available sum
output power of the voltage/current amplifiers and the AuxDC will occur
All other technical specifications (e.g. the maximum output power of a single
amplifier) are not affected
3
For an operational temperature above +30 °C (+86 °F) a duty cycle of down to
50 % may apply
4
PoE = Power over Ethernet
Miscellaneous
Weight
16.6 kg (36.6 lbs)
Dimensions (W x H x D, without handle) 450 x 145 x 390 mm (17.7 x 5.7 x 15.4 in)
PC connection
Two 10/100 Mbit/s PoE
4
Ethernet ports:
• 10/100 Mbit/s (10/100 Base-TX,
auto-sensing, auto-crossover, RJ45
connector for twisted pair cables)
• IEEE 802.3af compliant
• Port capability limited to one Class 1
(3.84 W) and one Class 2 (6.49 W)
powered device
Signal indication (LED)
> 42 V for voltage and current outputs
and AUX DC
Connection to ground (earth)
4 mm (0.16 in) banana socket (rear side)
Hardware diagnostics
Self diagnostics upon each start-up
Galvanically separated groups
The following groups are galvanically
separated from each other: mains, volt-
age amplifier output, current amplifier
group A/B, auxiliary DC supply, binary/
analog input
Protection
All current and voltage outputs are fully
overload and short circuit proof and
protected against external high-voltage
transient signals and over temperature
View and Download Yaesu FRT-7700 installation instructions online. Antenna tuner. FRT-7700 Tuner pdf manual download. Yaesu frt 7700 manual download.
Certifications
Developed and manufactured under an
ISO 9001 registered system
Technical Data CMC 356 (continued)
IEC 61850 GOOSE
1
Simulation
Mapping of binary outputs to data attributes in
published GOOSE messages.
Number of virtual binary outputs: 360
Number of GOOSEs to be published: 128
Subscription
Mapping of data attributes from subscribed
GOOSE messages to binary inputs.
Number of virtual binary inputs: 360
Number of GOOSEs to be subscribed: 128
Performance
Type 1A; Class P2/3 (IEC 61850-5).
Processing time (application to network or vice
versa): < 1 ms
VLAN support
Selectable priority and VLAN-ID
IEC 61850 Sampled Values (Publishing)
1
Specification
According to the “Implementation Guideline
for Digital Interface to Instrument Transformers
Using IEC 61850-9-2“ of the UCA International
Users Group
Sampling Rate
80 samples per cycle for nominal frequencies of
50 Hz and 60 Hz; synchronized with CMIRIG-B.
Synchronization
Synchronization attribute (smpSynch) is set
when the CMC is in synchronized operation
mode utilizing CMIRIG-B.
Sample count (smpCnt) zero is aligned with top
of the second (IRIG-B and PPS).
Accuracy data see above
VLAN support
Selectable priority and VLAN-ID
Max. number of SV streams
2 (with option LLO-2: 3 SV streams)
Power supply
Nominal input voltage
2
100 – 240 VAC, 1-phase
Permissible input voltage
85 .. 264 VAC
Nominal frequency
50/60 Hz
Permissible frequency range
45 .. 65 Hz
Power consumption
1.7 kVA at 115 V
/ 2.3 kVA at 230 V
Rated current
12 A at 115 V / 10 A at 230 V
Connection
Omicron Cmc 430
Standard AC socket (IEC 60320)
Environmental conditions
Operation temperature
3
0 .. +50 °C (+32 .. +122 °F)
Storage temperature
-25 .. +70 °C (-13 .. +158 °F)
Humidity range
Relative humidity 5 .. 95 %, non-condensing
Vibration
IEC 60068-2-6 (20 m/s
2
at 10 .. 150 Hz)
Shock
IEC 60068-2-27 (15 g/11 ms half-sine)
Safety Standards, Electromagnetic Compatibility
EMC
Omicron Cmc 256 Manual
The product adheres to the electromagnetic
compatibility (EMC) Directive 2004/108/EC
(CE conform).
Emission
Europe EN 61326-1; EN 61000-6-4; EN 61000-3-2/3
International IEC 61326-1;IEC 61000-6-4; IEC 61000-3-2/3
USA FCC Subpart B of Part 15 Class A
Immunity
Europe EN 61326-1; EN 61000-6-2;
EN 61000-4-2/3/4/5/6/11
International IEC 61326-1;IEC 61000-6-2;
IEC 61000-4-2/3/4/5/6/11
Safety
The product adheres to the low voltage
Directive 2006/95/EC (CE conform).
Europe EN 61010-1 Insulation of PC and SELV interfaces
complies with EN 60950-1
International IEC 61010-1
USA UL 61010-1
Canada CAN/CSA-C22.2 No 61010-1-04
Omicron Cmc 356 Manual Pdf
Ordering Information
CMC 356 with Test Universe Software
VE002801
CMC 356 Basic
VE002802
CMC 356 Protection
VE002803
CMC 356 Advanced Protection
CMC 356 with CMControl (without Test Universe Software)
VE002820
CMC 356 with CMControl-6
The CMControl can also be ordered as add-on together with a CMC 356
with Test Universe software or as a later upgrade.
Omicron Cmc
CMC 356 Hardware Options
VEHO2801
Option ELT-1 if ordered with a new unit
VEHO2802
Option ELT-1 if ordered as an upgrade
VEHO2803
Option LLO-2 if ordered with a new unit
Omicron 356 Manual
VEHO2804
Option LLO-2 if ordered as an upgrade