Omicron Cmc 356 User Manual Pdf

Omicron Cmc 356 User Manual Pdf Average ratng: 4,9/5 5892 reviews
Advertising

Omicron 356 Manual Get Download Omicron Cmc 356 User Manual And Access Online. Unlimited PDF Ebooks Download. Omicron 100TX to 100FX-SC Converter Connects the CMC 356, CMC 353 Measurement Systems. Jul 03, 2017  Get omicron cpc 100 user manual PDF file for free from our online library PDF file: omicron cpc 100 user manual Page: 1 2. OMICRON CPC 100 USER MANUAL The main topic of the following eBook is focused on OMICRON CPC 100 USER MANUAL, however it did not enclosed the possibility of other extra info as well as details concerning the topic.

  1. Consult OMICRON electronics's entire OMICRON Products and Solutions catalogue on DirectIndustry. Protection and recloser control testing 6-phase test sets + CMC 356 Universal relay test set and commissioning tool Test Universe PC software suite for advanced secondary testing with CMC test sets CMC 256plus High-precision relay test set PTL.
  2. Nov 24, 2015  On this page you can read or download omicron cmc 356 user manual in PDF format. If you don't see any interesting for you, use our search form on bottom ↓. CMC Exam Handbook - AACN. 4 CmC CertifiCation Program CMC ® (Cardiac Medicine Certification) is a nursing subspecialty designed for specialty certified nurses who.
  3. Oct 01, 2015  Choosing a Backup Generator Plus 3 LEGAL House Connection Options - Transfer Switch and More - Duration: 12:39. Bailey Line Road Recommended for you.
  4. Hire the Omicron CMC 356, a Universal Tool for Substation Commissioning, used by commissioning engineers worldwide. Hire online today with Inlec UK - Next Day Delivery Also Available.

1

Testing with GOOSE and Sampled Values functionality requires software licences for

the corresponding configuration modules

2

For line input voltages below 230 V, a derating of the simultaneously available sum

output power of the voltage/current amplifiers and the AuxDC will occur

All other technical specifications (e.g. the maximum output power of a single

amplifier) are not affected

3

For an operational temperature above +30 °C (+86 °F) a duty cycle of down to

50 % may apply

4

PoE = Power over Ethernet

Miscellaneous
Weight

16.6 kg (36.6 lbs)

Dimensions (W x H x D, without handle) 450 x 145 x 390 mm (17.7 x 5.7 x 15.4 in)
PC connection

Two 10/100 Mbit/s PoE

4

Ethernet ports:

• 10/100 Mbit/s (10/100 Base-TX,

auto-sensing, auto-crossover, RJ45
connector for twisted pair cables)

• IEEE 802.3af compliant
• Port capability limited to one Class 1

(3.84 W) and one Class 2 (6.49 W)
powered device

Signal indication (LED)

> 42 V for voltage and current outputs
and AUX DC

Connection to ground (earth)

4 mm (0.16 in) banana socket (rear side)

Hardware diagnostics

Self diagnostics upon each start-up

Galvanically separated groups

The following groups are galvanically
separated from each other: mains, volt-
age amplifier output, current amplifier
group A/B, auxiliary DC supply, binary/
analog input

Omicron Cmc 356 User Manual Pdf

Protection

All current and voltage outputs are fully
overload and short circuit proof and
protected against external high-voltage
transient signals and over temperature

View and Download Yaesu FRT-7700 installation instructions online. Antenna tuner. FRT-7700 Tuner pdf manual download. Yaesu frt 7700 manual download.

Certifications

Developed and manufactured under an
ISO 9001 registered system

Technical Data CMC 356 (continued)

IEC 61850 GOOSE

1

Simulation

Mapping of binary outputs to data attributes in
published GOOSE messages.
Number of virtual binary outputs: 360
Number of GOOSEs to be published: 128

Subscription

Mapping of data attributes from subscribed
GOOSE messages to binary inputs.
Number of virtual binary inputs: 360
Number of GOOSEs to be subscribed: 128

Performance

Type 1A; Class P2/3 (IEC 61850-5).
Processing time (application to network or vice
versa): < 1 ms

VLAN support

Selectable priority and VLAN-ID

IEC 61850 Sampled Values (Publishing)

1

Specification

According to the “Implementation Guideline
for Digital Interface to Instrument Transformers
Using IEC 61850-9-2“ of the UCA International
Users Group

Sampling Rate

80 samples per cycle for nominal frequencies of
50 Hz and 60 Hz; synchronized with CMIRIG-B.

Synchronization

Synchronization attribute (smpSynch) is set
when the CMC is in synchronized operation
mode utilizing CMIRIG-B.
Sample count (smpCnt) zero is aligned with top
of the second (IRIG-B and PPS).
Accuracy data see above

VLAN support

Selectable priority and VLAN-ID

Max. number of SV streams

2 (with option LLO-2: 3 SV streams)

Power supply
Nominal input voltage

2

100 – 240 VAC, 1-phase

Permissible input voltage

85 .. 264 VAC

Nominal frequency

50/60 Hz

Permissible frequency range

45 .. 65 Hz

Power consumption

1.7 kVA at 115 V

/ 2.3 kVA at 230 V

Rated current

12 A at 115 V / 10 A at 230 V

Connection

Omicron Cmc 430

Standard AC socket (IEC 60320)

Environmental conditions
Operation temperature

3

0 .. +50 °C (+32 .. +122 °F)

Storage temperature

-25 .. +70 °C (-13 .. +158 °F)

Humidity range

Relative humidity 5 .. 95 %, non-condensing

Vibration

IEC 60068-2-6 (20 m/s

2

at 10 .. 150 Hz)

Shock

IEC 60068-2-27 (15 g/11 ms half-sine)

Safety Standards, Electromagnetic Compatibility
EMC

Omicron Cmc 256 Manual

Omicron cmc 256 manual

The product adheres to the electromagnetic
compatibility (EMC) Directive 2004/108/EC
(CE conform).

Emission

Europe EN 61326-1; EN 61000-6-4; EN 61000-3-2/3

International IEC 61326-1;IEC 61000-6-4; IEC 61000-3-2/3

USA FCC Subpart B of Part 15 Class A

Immunity

Europe EN 61326-1; EN 61000-6-2;

EN 61000-4-2/3/4/5/6/11

International IEC 61326-1;IEC 61000-6-2;

IEC 61000-4-2/3/4/5/6/11

Safety

The product adheres to the low voltage
Directive 2006/95/EC (CE conform).

Europe EN 61010-1 Insulation of PC and SELV interfaces

complies with EN 60950-1

International IEC 61010-1

USA UL 61010-1

Canada CAN/CSA-C22.2 No 61010-1-04

Omicron Cmc 356 Manual Pdf

Ordering Information

CMC 356 with Test Universe Software

VE002801

CMC 356 Basic

VE002802

CMC 356 Protection

VE002803

CMC 356 Advanced Protection

CMC 356 with CMControl (without Test Universe Software)

VE002820

CMC 356 with CMControl-6

The CMControl can also be ordered as add-on together with a CMC 356
with Test Universe software or as a later upgrade.

Omicron Cmc

CMC 356 Hardware Options

VEHO2801

Option ELT-1 if ordered with a new unit

VEHO2802

Option ELT-1 if ordered as an upgrade

VEHO2803

Option LLO-2 if ordered with a new unit

Omicron 356 Manual

VEHO2804

Option LLO-2 if ordered as an upgrade